An HVLS fan covers over 1500 m². It must be cooled in the factory and ventilated in the large rooms. Operation of the High Volume Industrial Ceiling Fans consumes less energy than a conventional low-speed volume blower, saving more money in the long term.
Products Description
An HVLS fan covers over 1500 m². It must be cooled in the factory and ventilated in the large rooms. Operation of the High Volume Industrial Ceiling Fans consumes less energy than a conventional low-speed volume blower, saving more money in the long term. Besides the cost-effective circulation of large air volumes, HVLS industrial ceiling fans offer some other benefits for industrial, commercial, and agricultural enterprises. Industrial ceiling fans are powerful because they are designed for use in a wide range of industrial and commercial applications, from ventilation and ventilation systems to air conditioning systems. Specialties include sizeable open-plan company buildings that provide high-quality lighting, ventilation, and air quality control. RTFANS carries fans, management, and accessories for industrial ceilings.
Large ceiling fans ensure massive air movements in industrial and commercial areas and are durable and cost-effective. What sets them apart from the fans for residential ceilings is their high capacity, high efficiency, and high performance. With large units that provide maximum torque, can operate industrial ceiling fans at night to avoid distractions. The Humongous Fan also offers a high performance, specially developed blade, high capacity, and high efficiency. These fans are also ideal for those who love the sound of high volume air movements in industrial and commercial areas. We have a High volume industrial ceiling fans, which we prefer for industrial applications such as air conditioning, heating, ventilation, and air conditioning.
One of the essential factors in choosing an industrial ceiling fan is the amount of air you need to circulate. If you have large ceiling fans that keep the air moving, there is less risk of moisture accumulating, which is less of a problem for the ventilation system you will choose.
MPN | RTF-FF-7E | RTF-FF-6E | RTF-FF-5E |
Fan Dia. | 7.3m/24ft | 6.1m/20ft | 5.5m/18ft |
Power | 1.1/1.5 | 1.1/1.5 | 1.1/1.5 |
Air Flow(m³/min) | 12,600 | 11,200 | 9,800 |
Current | 4.1/2.4A | 4.1/2.4A | 4.1/2.4A |
Application Area | 1,600m² | 1,200m² | 850m² |
Noise | 42dB | 42dB | 42dB |
Weight | 115 | 110 | 105 |
Product Advantages
- German “Nord” Customizedcoaxialbevelreductiongears With Diameter Ofaxle 40mm
- German “Simrit”Double Oil Sealdesign,Durableandreliable “Shell”
- opclass “Omala” S4 Lubrication Oil, Zeromaintenancefor Over 20000 Hours
- IE3 High Efficiencymotor With Imported“SKF-VL”Bearing, Save Energyby 10-15% Than IE1motor.
Innovativedouble Chassisdesign,Moredurableandsteady
Importedaeronauticaluminumalloy (Aa7075)
Forgedby 1000Tmachine With 570Mpaextension Strength
T6 Heatprocessing
High Strength Aircraft Aluminum Alloy:AA6063T6511, PVFD Surface Coating.
Patented Airfoil Design, And Special Reinforcing Rib Supporting System, Increase The Strength And Flexibility.
Inner Equipped Steel Cable Design To Prevent Fan Blade Falling
Unique Cardan Joint Design, Working As A Human Beings’ Joint, This Allows The Fan To Find Its Own Vertical Position No Matter What The Slope Of The Building, And Helps To Decrease The Shocking Of Fan During Running.
Denmark “DANFOSS"VFD Inverter, With Stepless Speed Regulation.
IP55motorprotectiongradeand NEMA1 Standardcontrolbox.
"Schneider"Brandelectrical Sets, With Safetyprotection Module Inside.
"Mortise And Tenon Joint Structure" Welded By Robot, Traditional Technique With Double Guarantee On Q345B High-Strength Structural Steel
Anti-skip design, more safety and reliable.
H beam, Rigid frame and Concrete installation structure are options, and customized for special building structure.
6 Pcs Airfoils Are Connected Into A Whole With 6 Pcs Safety Retainer.
Product FEATURER
large area coverage with minimal power use
In essence, Silent is more muffled than a human discussion.
tridimensional wind coming from every anglecompact a
nd stylish-looking
Comfortable, gentle breeze that is natural
No upkeep required, long lifespan
Factory
Installation Conditions
Certificate
FAQ
HVLS fans have longer and larger blades, which move more air than traditional ceiling fans, covering a larger area. HVLS fans also operate at a lower speed, consuming less energy.
Yes, HVLS fans can be used in agricultural settings to increase air circulation and reduce hot spots in barns, dairies, and greenhouses.
Yes, HVLS fans can work in tandem with HVAC systems to reduce energy consumption and improve air circulation in large commercial or industrial buildings.
The right HVLS fan is determined by the size of the space and the desired level of air movement. A professional technician can help in choosing the right HVLS fan.
HVLS fans are installed on building structures such as beams or ceilings. The installation process requires a professional technician for safety reasons.
By reducing heat and humidity in industrial settings, HVLS fans improve air quality, reduce health risks, and enhance overall employee comfort and productivity.
HVLS fans require regular cleaning and maintenance to ensure optimal performance. Maintenance requirements vary depending on the fan type and usage.
Yes, HVLS fans can lead to significant energy savings in commercial settings by reducing the workload of HVAC systems and improving air circulation, thereby lowering energy consumption and costs.